Intravascular Lithotripsy (IVL)
This product is available only in Greece and Cyprus
Shockwave Intravascular Lithotripsy (IVL) technology leverages the familiarity of angioplasty balloon catheters to provide a safe, effective and intuitively understandable procedure when treating complex calcified lesions.
Miniaturized and arrayed lithotripsy emitters create a localized field effect at the site of the calcium. Optimized energy for the treatment of cardiovascular calcium.
- Coronary Intravascular Lithotripsy – Shockwave C2+.
- Peripheral Intravascular Lithotripsy – Shockwave M5+ & Shockwave S4 Kit.
NEW Peripheral IVL – Shockwave L6 Large Vessel Treatment
PREDICTABLY SAFE: Establish a new standard of care for safe calcium modification by reducing the risk of perforations and other complications to make procedures more predictable.
DISTINCTLY INTUITIVE: Optimally modify calcium from the very first case via a unique mechanism of action in an intuitive platform.
CONSISTENTLY EFFECTIVE: Achieve excellent lumen gains and stent expansion consistently despite the calcium morphology – whether superficial or deep, concentric, or eccentric, and short or long lesions.
Learn More About How IVL Was Developed by Watching:
THE +PLUS SIDE OF CORONARY IVL, Shockwave C2+:
Watch here:
PULSES: Additional pulses needed for eccentric and nodular calcium along the treatment lesion.
EFFICIENCY: Single-cather modification of longer calcified lesions.
PRACTICALITY: A sterile sleeve for the connector cable is now packaged with each catheter.
On The +Plus Side of Peripheral Intravascular Lithotripsy, Shockwave M5+ & S4 kit
FASTER: Save Procedure Time With Quicker Cycle Time.
Watch here:
FURTHER: Broaden Access Options With an Increased Catheter Working Length of 135cm.
Above The Knee
- Enables radial access to iliac and common femoral arteries;
- Allows brachial access to popliteal artery.
Below The Knee
- Enables contralateral access to tibial arteries;
- Allows treatment of lesions over 20cm in length.
LARGER: Optimally treat larger diameter vessels with an 8.0mm size, designed for:
- Large bore access preparation;
- Treating symptomatic iliacs;
- Treating the common femoral artery.
Introducing the New Shockwave L6 Peripheral IVL Catheter
BE LARGE & IN CHARGE
Purpose-built to address challenging calcium in large vessels
Watch here:
- LARGE VESSEL TREATMENT
8.0, 9.0, 10.0 & 12.0mm diameter sizes. - CONSISTENT HIGH ENERGY
Compact emitter design. - FOCUSED TREATMENT
30mm balloon length. - SUPPORT YOU NEED
018” guidewire. - ULTRA-LOW PRESSURE
IVL therapy at 2-4 atm.
Download brochure here:
Need help?